YK11-0016-DI-002-08
49
Inverter settings can be changed by the customer list
※
3
No.
Name
Range No.
Parameter Name
Setting Range
Unit
Description
1
A2-01
User
Parameter 1
b1-01
Frequency Reference Selection1※1
1
Terminals-Analog
input terminal
2
A2-02
User
Parameter2
C6-02
Carrier Frequency Selection
o2-04 to the
dependet
Set the carrier
frequency
3
A2-03
User
Parameter3
d1-02
Frequency Reference
Selection 2
(Multi-Step Speed Reference1) ※2
40
Hz
Switching S5 ON
4
A2-04
User
Parameter4
d1-03
Frequency Reference
Selection 3
(Multi-Step Speed Reference2) ※2
30
Hz
Switching S6 ON
5
A2-05
User
Parameter5
d1-04
Frequency Reference
Selection 4
(Multi-Step Speed Reference3) ※2
0
Hz
Switching S5+S6
ON
6
A2-06
User
Parameter6
H1-04
Multi-Function Digital Input Terminal
S4 Function Selection
14
Fault Reset
7
A2-07
User
Parameter7
H1-05
Multi-Function Digital Input Terminal
S5 Function Selection
3
Multi-Step Speed
Reference 1
8
A2-08
User
Parameter8
H1-06
Multi-Function Digital Input Terminal
S6 Function Selection
4
Multi-Step Speed
Reference 2
9
A2-09
User
Parameter9
H2-01
Terminal MA,MB and MC Function
Selection(relay)
000E
Fault
10
A2-10
User
Parameter10
H2-02
Terminal P1 Function Selection(open-
collector)
0
During Run
11
A2-11
User
Parameter11
H2-03
Terminal P2 Function Selection(open-
collector)
2
Speed Agree 1
12
A2-12
User
Parameter12
H3-09
Terminal
A2
Signal
Level
Selection(Sets the input signal level for
terminal A2)
2
4 to 20mA
13
A2-13
User
Parameter13
H3-10
Terminal A2 Function Selection. Sets
the function of terminal A2
0
Frequency Bias
14
A2-14
User
Parameter14
H3-11
Terminal A2 Gain Setting
100
%
20mA at 100%
15
A2-15
User
Parameter15
H3-12
Terminal A2 Input Bias
0
%
4mA at 0%
16
A2-16
User
Parameter16
H4-01
Multi-Function Analog Output Terminal
AM
102
Output Frequency
17
A2-17
User
Parameter17
H4-02
Multi-Function Analog Output Terminal
AM Gain
100
%
10V at 100%
18
A2-18
User
Parameter18
H4-03
Multi-Function Analog Output Terminal
AM Bias
0
%
0V at 0%
※
1: PMB100D has been set to "b1-01 = 0". When performing a main speed frequency reference analog input,
Please set to "b1-01 = 1".
PMB300,600,1200,2400D, please do not to "b1-01 = 0". It may cause malfunction.
※
2: On the performance of the pump, it can not be set to more than 60Hz.
※
3: This is a case of standard setting. If you change the settings in the customer behavior I ask you for
confirmation by the customer.
CAUTION
That can be changed constant in customers has been stored in the Favorites.
If you want to change your favorite setting, you can change in the setup mode
(STUP). For more information, please refer to the inverter instruction manual.
Other settings can not be changed by the customer.
Details of constants, please refer to the inverter instruction manual.
Summary of Contents for PMB100D
Page 2: ......
Page 3: ...Declaration of Conformity...
Page 39: ...YK11 0016 DI 002 08 12 2 4 Dimensional drawing Fig 11 Dimensional drawing PMB100D...
Page 40: ...YK11 0016 DI 002 08 13 Fig 12 Dimensional drawing PMB300D...
Page 41: ...YK11 0016 DI 002 08 14 Fig 13 Dimensional drawing PMB600D...
Page 42: ...YK11 0016 DI 002 08 15 Fig 14 Dimensional drawing PMB1200D...
Page 43: ...YK11 0016 DI 002 08 16 Fig 15 Dimensional drawing PMB2400D...
Page 62: ...YK11 0016 DI 002 08 35...
Page 65: ...YK11 0016 DI 002 08 38...
Page 72: ...YK11 0016 DI 002 08 45...
Page 84: ...YK11 0016 DI 002 08 57 Fig 28 PMB300D Optional attachment figure...
Page 85: ...YK11 0016 DI 002 08 58 Fig 29 PMB600D Optional attachment figure...
Page 86: ...YK11 0016 DI 002 08 59 Fig 30 PMB1200D Optional attachment figure...
Page 89: ...YK11 0016 DI 002 08 62 Fig 33 Dimensional drawing PMB2400D Horizontal exhaust model...
Page 99: ...YK11 0016 DI 002 08 72...
Page 105: ...YK11 0016 DI 002 08 78...
Page 119: ......