![Ulvac PMB100D Instruction Manual Download Page 67](http://html1.mh-extra.com/html/ulvac/pmb100d/pmb100d_instruction-manual_4492079067.webp)
YK11-0016-DI-002-08
40
CAUTION
Be sure to put in the Insert if you use any plastic made product such
as nylon tube. Such a tube is likely to cause deformation or get rigid
as secular distortion and might cause a water leakage.
Keep the environment that does not cause dew formation when the
cooling water temperature was lower.
CAUTION
The machine is designed not to cause any leakage under restricted
condition and demonstrated by the Leak test.
However, it still has a risk of leaking under any abnormal condition
other than specified, for example abnormal water pressure rise. In
such a case, the leakage shall remain unstopped unless the supply
from the system stops.
You should refrain from installing electrical equipment or wiring
beneath the Pump and on the floor around the Pump.
We recommend you to put the Leak sensor on the floor beneath the
Pump and engage it with the interlock system of the equipment.
Close the Coolant supply valve (HWSV) immediately you noticed the
leakage. Put the [Closed] tag onto the handle after having closed the
valve.
Put a Flow meter applicable to visually check the flow onto the
cooling water supply source to make it possible to check the flow.
CAUTION
The water included little impurities (ex. Industrial Water) is
recommended for cooling water.
Depending on the water quality, the inside wall of cooling water
tube is covered with water scale (CaCO3 etc.) and cooling water
flow rate may be decreased.
Cooling water tube is corroded by Chlorine ion (Cl-) and cooling
water leak may be caused.
In case of using pure water, cooling water leak may be caused by
metal component dissolution, too.
In these cases, the repair service may be for a fee.
Establishment: Japan Industrial Water Association
Summary of Contents for PMB100D
Page 2: ......
Page 3: ...Declaration of Conformity...
Page 39: ...YK11 0016 DI 002 08 12 2 4 Dimensional drawing Fig 11 Dimensional drawing PMB100D...
Page 40: ...YK11 0016 DI 002 08 13 Fig 12 Dimensional drawing PMB300D...
Page 41: ...YK11 0016 DI 002 08 14 Fig 13 Dimensional drawing PMB600D...
Page 42: ...YK11 0016 DI 002 08 15 Fig 14 Dimensional drawing PMB1200D...
Page 43: ...YK11 0016 DI 002 08 16 Fig 15 Dimensional drawing PMB2400D...
Page 62: ...YK11 0016 DI 002 08 35...
Page 65: ...YK11 0016 DI 002 08 38...
Page 72: ...YK11 0016 DI 002 08 45...
Page 84: ...YK11 0016 DI 002 08 57 Fig 28 PMB300D Optional attachment figure...
Page 85: ...YK11 0016 DI 002 08 58 Fig 29 PMB600D Optional attachment figure...
Page 86: ...YK11 0016 DI 002 08 59 Fig 30 PMB1200D Optional attachment figure...
Page 89: ...YK11 0016 DI 002 08 62 Fig 33 Dimensional drawing PMB2400D Horizontal exhaust model...
Page 99: ...YK11 0016 DI 002 08 72...
Page 105: ...YK11 0016 DI 002 08 78...
Page 119: ......