YK11-0016-DI-002-08
24
2.8 Motor control equipment (water-cooled type with atmospheric pressure
operating specification inverter) (optional)
Please refer to Section 5.4.
WARNING
For the operation of the controller and electrical wiring,
refer to the instruction manual for the inverter.
Troubles imputable to control by other than the standard controller
and to change of setting are not covered by this warranty.
Configuration and control wiring for the start, has been set at the
factory.
When starting the pump by remote operation, however, disconnect
the control wiring for the start-up and turn ON/OFF the mechanical
no-voltage contact to start/stop.
When you use the atmospheric actuation specification, in the
control equipment used in the PMB-D series, an appropriate setting
for each pump operation is performed. If you examine the special
use method (When changing the parameter of the control
equipment), consult with our company.
Furthermore, this pump guarantees reliability by the operation
frequency 50Hz and 60Hz.
2.9
Motor control equipment (air-cooled type with atmospheric pressure operating
specification inverter) (optional)
Please refer to Section 5.4
WARNING
For the operation of the controller and electrical wiring,
refer to the instruction manual for the inverter.
Troubles imputable to control by other than the standard controller
and to change of setting are not covered by this warranty.
Configuration and control wiring for the start, has been set at the
factory.
When starting the pump by remote operation, however, disconnect
the control wiring for the start-up and turn ON/OFF the mechanical
no-voltage contact to start/stop.
When you use the atmospheric actuation specification, in the control
equipment used in the PMB-D series, an appropriate setting for each
pump operation is performed. If you examine the special use method
(When changing the parameter of the control equipment), consult
with our company.
Furthermore, this pump guarantees reliability by the operation
frequency 50Hz and 60Hz.
Summary of Contents for PMB100D
Page 2: ......
Page 3: ...Declaration of Conformity...
Page 39: ...YK11 0016 DI 002 08 12 2 4 Dimensional drawing Fig 11 Dimensional drawing PMB100D...
Page 40: ...YK11 0016 DI 002 08 13 Fig 12 Dimensional drawing PMB300D...
Page 41: ...YK11 0016 DI 002 08 14 Fig 13 Dimensional drawing PMB600D...
Page 42: ...YK11 0016 DI 002 08 15 Fig 14 Dimensional drawing PMB1200D...
Page 43: ...YK11 0016 DI 002 08 16 Fig 15 Dimensional drawing PMB2400D...
Page 62: ...YK11 0016 DI 002 08 35...
Page 65: ...YK11 0016 DI 002 08 38...
Page 72: ...YK11 0016 DI 002 08 45...
Page 84: ...YK11 0016 DI 002 08 57 Fig 28 PMB300D Optional attachment figure...
Page 85: ...YK11 0016 DI 002 08 58 Fig 29 PMB600D Optional attachment figure...
Page 86: ...YK11 0016 DI 002 08 59 Fig 30 PMB1200D Optional attachment figure...
Page 89: ...YK11 0016 DI 002 08 62 Fig 33 Dimensional drawing PMB2400D Horizontal exhaust model...
Page 99: ...YK11 0016 DI 002 08 72...
Page 105: ...YK11 0016 DI 002 08 78...
Page 119: ......