YK11-0016-DI-002-08
80
Trouble
Causes
Processing Method
Reference
Water leak
outside
the Pump.
1
Coolant joints and so on
got loose, or not tighten.
Check and repair Joints and
so on.
3.6
6.2.5
Rotation is
uneven, and
so it was
going not to
rotate
gradually.
1
Are all three phases of
power supply normal?
Abnormal phase voltage.
Check the power supply.
3.5
2
Oil is dirty.
Replace with new oil.
Conduct the overhaul.
(Inside cleaning)
3.2
6.2.1
6.2.2
6.2.3
3
Foreign substance entered
inside the Pump impaired
the Motor rotation.
Conduct the overhaul.
Removal of foreign substance
inside the Pump.
6.2.8
6.4
Initially,
performanc
e was being
satisfied,
but the
vacuum
degree
became
decreased.
1
Foreign substance entered
in the Pump.
Scar on the rotor surface.
Conduct the overhaul
(replacement of the Casing,
Rotor, Cover and so on.)
2.2
6.2.8
6.4
Summary of Contents for PMB100D
Page 2: ......
Page 3: ...Declaration of Conformity...
Page 39: ...YK11 0016 DI 002 08 12 2 4 Dimensional drawing Fig 11 Dimensional drawing PMB100D...
Page 40: ...YK11 0016 DI 002 08 13 Fig 12 Dimensional drawing PMB300D...
Page 41: ...YK11 0016 DI 002 08 14 Fig 13 Dimensional drawing PMB600D...
Page 42: ...YK11 0016 DI 002 08 15 Fig 14 Dimensional drawing PMB1200D...
Page 43: ...YK11 0016 DI 002 08 16 Fig 15 Dimensional drawing PMB2400D...
Page 62: ...YK11 0016 DI 002 08 35...
Page 65: ...YK11 0016 DI 002 08 38...
Page 72: ...YK11 0016 DI 002 08 45...
Page 84: ...YK11 0016 DI 002 08 57 Fig 28 PMB300D Optional attachment figure...
Page 85: ...YK11 0016 DI 002 08 58 Fig 29 PMB600D Optional attachment figure...
Page 86: ...YK11 0016 DI 002 08 59 Fig 30 PMB1200D Optional attachment figure...
Page 89: ...YK11 0016 DI 002 08 62 Fig 33 Dimensional drawing PMB2400D Horizontal exhaust model...
Page 99: ...YK11 0016 DI 002 08 72...
Page 105: ...YK11 0016 DI 002 08 78...
Page 119: ......