background image

en

Operating instructions

flexoTHERM exclusive

VWF 57 - 197/4, VWF 57 - 117/4 230V

 0020213396_05   -   16.01.2023

Summary of Contents for flexoTHERM exclusive VWF 57/4

Page 1: ...en Operating instructions flexoTHERM exclusive VWF 57 197 4 VWF 57 117 4 230V 0020213396_05 16 01 2023...

Page 2: ...e target cylinder temperature 11 5 9 Yield indicator 11 5 10 Displaying the Live Monitor 12 5 11 Displaying the building circuit pressure 12 5 12 Displaying the environment circuit pressure 12 5 13 Re...

Page 3: ...ation components compliance with all inspection and maintenance conditions listed in the instructions This product can be used by children aged from 8 years and above and persons with reduced physica...

Page 4: ...and elec tricity supply lines The drain pipework and expansion relief valve for the heat source circuit to constructional condi tions that may affect the operational reliability of the product 1 2 4...

Page 5: ...qualified to work with refrigerants services the product and after decommis sioning recycles or disposes of it 1 2 9 Avoid environmental damage caused by escaping refrigerant The product contains the...

Page 6: ...ply only to Validity Great Britain OR Ireland Product VWF 57 4 VWF 87 4 VWF 117 4 VWF 157 4 VWF 197 4 Validity Great Britain OR Ireland Product VWF 57 4 230 V VWF 87 4 230 V VWF 117 4 230 V 3 System o...

Page 7: ...cording of the values only includes the product in the factory delivered condi tion Supplementary accessories even if they are installed on the product as well as any other components in the heating s...

Page 8: ...three times in a row it is switched off and a fault message is displayed 4 5 5 Pump and valve blocking protection system This function prevents the pumps for heat ing water and brine and all diverter...

Page 9: ...start the electric back up heater A fault message is displayed that can only be reset by pressing the Reset button or by switching the heat pump off and on again Max heating circuit temperature 85 5 O...

Page 10: ...Sym bol Meaning Explanation Compressor Filled Com pressor in op eration Not filled Compressor not in operation Sym bol Meaning Explanation bar Current filling pressure of the heating system The dashed...

Page 11: ...product once the cas ing has been completely closed 5 7 Switching on the product Use the partition that is installed on site e g fuses or power switches to switch on the product 5 8 Adjusting the targ...

Page 12: ...3 Reading the operating statistics Menu Information Heating op hours Menu Information DHW operating hours Menu Information Cooling op hours Menu Information Total operating hours You can use this func...

Page 13: ...cloth and a little solvent free soap Do not use sprays scouring agents detergents solvents or cleaning agents that contain chlorine 7 3 Reading maintenance messages If the symbol is shown in the displ...

Page 14: ...any destruction Otherwise the batteries are disposed of to gether with the product In accordance with the legal regula tions used batteries must be returned since batteries may contain substances tha...

Page 15: ...en to the user for safe keeping during the hand over process Installers should also at this time advise the user of the an nual servicing requirements and advise of appropriate service agreement Terms...

Page 16: ...e Total Heating Cumulative value Energy yield Month Domestic hot water Cumulative value kWh Working figure Month Domestic hot water Cumulative value Energy yield Total Domestic hot water Cumulative va...

Page 17: ...ed Immersion heater power Current value kW Information Contact details Phone number Serial number Permanent value Operating hours total Cumulative value h Hours heating Cumulative value h DHW operatin...

Page 18: ......

Page 19: ......

Page 20: ...isher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 2191 18 0 Fax 49 2191 18 2810 info vaillant de www vaillant de These instructions or parts thereof are protected by copyrigh...

Reviews: