3-4
Edition March 1995
3 - Control Panel
■
Push Button Controls
■
Jog Button
The Jog Button permits the manual operation of the film advance.
As long as the button is held depressed, the film will advance, the
LED will be blinking on and off, and the LCD will display "FILM
ADVANCE". Releasing the Jog Button will cause the film to stop
advancing, the LED to stop blinking, and the LCD will display
"READY". This can be used for added inter-job spacing, for
checking on film feeding when reloading film, and for confirmation
of the operational status of the drive circuit. During a JOG, the
OOMS (Out Of Media Sensor) and the JAM sensor are ignored to
allow loading of the film.
■
Film Advance Button
Depressing the Film Advance Button will automatically advance
the film by the number of inches that has been programmed into
the film advance register (See "Changing Default Settings" on
page 5-1, for setting film advance length). While the film is
advancing, the LED will be blinking and the LCD will display "FILM
ADVANCE". When the film has stopped advancing, the LCD will
display "READY" and the LED will stop blinking.
3000/4000 UM : Chapter 3 (Controls) Page 4 Wednesday, September 4, 1996 8:28 AM