www.ultratecfx.com
10
Data Out
The system is connected via a 5-pin XLR communications cable. The communication chain is started
from the 5-pin XLR connector on the rear panel of the SUREFIRE DIGITAL controller.
Pickle Input
There is an XLR connector for an external firing device. (ie. pyro pickle) Pins 1 and 2 are used.
SureFire Pyrologic Controller Rear Panel
Match Test/Continuity Update
The Green LED on the channel select buttons of the controller indicates there is continuity at the
channel indicated. Matches on all slaves can be displayed by selecting the slave address on the
module select encoder. This feature will also determine if the expected slave module is On Line. If
the operator expects to see matches on the selected slave and none appear, the slave is not ON Line
or the SAFE/ARMED key is not in SAFE position.
In ARMED mode, match and remote status are not updated, the controller holds the last up date.
To update status, the controller must be switched into SAFE mode (Red control LED OFF) and SLAVE
POWER ‘ON’. (yellow control LED ON).
MIDI In
5 Pin Din Connector. Pin Out:
MIDI Pickle Input
There is an XLR connector for an external enabling device. (ie. pyro pickle) Pins 1 and 2 are used.
Used with MIDI Controlled shows
DOWN ARROW
Scrolls LCD display DOWN Cue to Cue. (1, 2, 3, 4, 5, 6...etc.). Also used at some prompt screens.
RIGHT ARROW
Scrolls LCD displayed information Left to Right. For review of Cue data only.
LEFT ARROW
Scrolls LCD displayed information Right to Left. For review of Cue data only.