4.8
MAINTENANCE
Supervisor Menu on Digital Panel
Figure 4.7
# PROGRAMS: 10
SECURITY: NO
COOLDOWN: 4.0
TEST: YES
NO
YES
PROGRAM
NO
YES
PROGRAM
NO
YES
PROGRAM
NO
YES
PROGRAM
-
+
-
+
-
+
-
+
COOLDOWN is the time that the machine
waits after sealing the bag/pouch before
the seal bars retract. This allows time for
the actual seal to cool down and take a set.
The range is from 1 to 8 seconds.
Press the MENU key.
SECURITY can be turned on by selecting
yes. If security is on, the operator menu will
be read only and the operator will not be
able to change any settings.
Press the MENU key.
This is how you specify the maximum
number of programs that may be saved in
memory. Each program may have its own
set of unique parameters.
This range is from 1 to 10.
Press the MENU key.
If TEST is set to YES (using the up arrow
key), the vacuum valve and vent valve may
be operated manually. The up arrow key
activates the vacuum valve, the down arrow
key activates the vent valve, and pressing
both at the same time turns them both off.
As you activate either valve, the vacuum
pressure is displayed.
Press the MENU key.
Summary of Contents for ULTRAVAC 2100
Page 2: ......
Page 81: ......
Page 90: ...9 ...
Page 91: ...10 ...
Page 93: ...12 13 ...
Page 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Page 102: ...22 ...
Page 105: ......
Page 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...