THE NEW STANDARD FOR
INNOVATION
• [email protected] • UltraSourceUSA.com
UltraSource LLC • 1414 West 29th Street • Kansas City, MO 64108-3604 USA • 800.777.5624 • 816.753.2150
5.1
SCHEMA
TICS
SCHEMATICS
Designation and Function of Controls
The following designations are found on the Electrical Diagrams:
Manually Activated Switches and Buttons:
SW-1
On/off control power
SW-3
On/off gas flush
SW-4
Quick seal (Optional)
Limit Switches:
LS-1
Left chamber cycle start
LS-2
Right chamber cycle start
Contactors:
C-1
Vacuum pump
C-2
Seal impulse
C-3
Redundant seal impluse
Overloads and Fusing:
OL-1
Vacuum pump motor
F-3
Control power fuse
Control Modules:
MCM
Master control module
R-1
Redundant seal impluse
contactor timer
Control Lights:
LT-1
On/off control power
light (green)
LT-2
Seal impulse on light
(red)
Transformers:
T-1
Seal impulse, front
T-2
Seal impulse, rear
T-3
Control power
Motors:
M-1
Vacuum pump
Solenoid Valves:
SOL-1
Vacuum flush solenoid
SOL-2
Gas flush solenoid
SOL-3
Seal bladder solenoid
SOL-4
Ventilation solenoid
Mechanically Activated Switches
(Pneumatic Diagram only):
V-1
Gas selector valve
Summary of Contents for ULTRAVAC 2100
Page 2: ......
Page 81: ......
Page 90: ...9 ...
Page 91: ...10 ...
Page 93: ...12 13 ...
Page 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Page 102: ...22 ...
Page 105: ......
Page 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...