THE NEW STANDARD FOR
INNOVATION
• [email protected] • UltraSourceUSA.com
UltraSource LLC • 1414 West 29th Street • Kansas City, MO 64108-3604 USA • 800.777.5624 • 816.753.2150
4.3
MAINTENANCE
Seal Bar Maintenance (continued)
Step 4.
Insert the new seal element through the hole in the brass contact. Leave about 3/4-in.
of excess seal element extending past the brass contact and tighten the clamping screw.
Insert the other end of the element through brass contact on the opposite end of the seal
bar. Place a slotted tip screwdriver on top of the seal element and against the brass contact
where the seal element exits. Using the tightening tool provided (or needle nose pliers),
tighten the seal element as shown.
Step 5.
While maintaining tension on the tightening tool, use the slotted tip screwdriver to tighten
the clamping screw.
NOTE:
A 1.5mm Allen wrench will be needed to tighten the clamping screws on a Double
Seam seal bar.
Step 6.
Check the tension of the seal element by pulling it up at the middle of the bar. The seal
element should not pull beyond 3/16-in. of the seal bar. If there is not enough tension,
tighten as necessary. Elements may break in the middle of the bar if tension is not set
properly. Install the new Teflon
®
tape strip over the bar.
3/16-in. maximum
Figure 4.4
Figure 4.5
Summary of Contents for ULTRAVAC 2100
Page 2: ......
Page 81: ......
Page 90: ...9 ...
Page 91: ...10 ...
Page 93: ...12 13 ...
Page 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Page 102: ...22 ...
Page 105: ......
Page 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...