4.6
MAINTENANCE
Troubleshooting
Problem
Indications
Remedy
Improper or no
sealing
Bladder light on control
module is lit but the seal bar
does not come down
Check to make sure that the
regulator knob is turned fully
clockwise, or, if air-assist is used,
set to the recommended pressure
Check seal bladder valve SOL-3
for proper operation
The seal bar is not heating
up even though the red
seal light on the front panel
comes on
Check seal bar connection points
and clips for corrosion and proper
tension
The red seal light on the
front panel either does not
light for the proper length
of time (1/2 to 1 second) or
does not light at all
Check for broken seal element
Check seal bar fuse F-1 for front
seal bar and F-2 for rear seal bar*
Make sure the seal impulse
potentiometer POT-3 is set high
enough or check for defective
control module
Front or rear seal bar
heating, but not both
Check seal bar fuse F-1 for front
seal bar and F-2 for rear seal bar*
* Fuses F-1 and F-2 only apply to machines shipped before 1/1/2006.
NOTE:
For proper sealing, three things must occur:
1. The seal bar must come down and place adequate pressure between the seal bar and
the backup strip.
2. The seal element must heat up sufficiently to fuse the pouch.
3. The pouch must be allowed to cool for a time to ensure a good “set.”
Summary of Contents for ULTRAVAC 2100
Page 2: ......
Page 81: ......
Page 90: ...9 ...
Page 91: ...10 ...
Page 93: ...12 13 ...
Page 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Page 102: ...22 ...
Page 105: ......
Page 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...