SAFETY
Machine Conformity
This machine has been manufactured to conform to the following safety standards:
UL 73, Motor Operated Appliances, USA
The Ultravac 2100 is manufactured to conform to the relevant provisions of ANSI/UL-73,
Tenth Edition dated 03/2011, Revised 01/2012.
CSA 22.2, No. 68, Motor Operated Appliances, Canada
The Ultravac 2100 is manufactured to conform to the relevant provisions of CSA C22.2 No.
68-09, Seventh Edition, Update #2 dated 09/2010.
CE Low Voltage Directive (LVD) 2006/95/EC
The Ultravac 2100 is manufactured to conform to the relevant provisions of
• EN 60335-1-2012 relating to “Safety of household and similar electrical appliances,”
• EN 60335-2-64:2000 relating to “Particular requirements for commercial electric kitchen
machines.”
and overall the provisions of Low Voltage Directive (LVD) 2006/95/EC relating to
“Equipment designed for use within certain voltage limits of 12 December 2006.”
CE Electromagnetic Compatibility (EMC) Directive 89/336/EEC
The Ultravac 2100 is manufactured to conform to the relevant provisions of
• EN 61000-6-4 relating to “Emissions, Radiated, 30Mhz - 1Ghz”
• EN 61000-6-2 relating to “Emissions, Conducted, 150kHz - 30Mhz”
• EN 61000-4-2 relating to “Immunity ESD ± 4kV Contact/ ±8kV air discharge “
• EN 61000-4-3 relating to “Immunity Radiated RF, 10V/m, 80Mhz - 2.7Ghz”
• EN 61000-4-4 relating to “Immunity EFT (Mains) ±1kV”
• EN 61000-4-5 relating to “Immunity Surge AC, ±2kV”
• EN 61000-4-6 relating to “Immunity Conducted RF (Mains), 10Vrms.”
and overall the provisions of “Electromagnetic Compatibility (EMC) Directive 89/336/EEC of
15 December 2004.”
USDA / AMI Sanitary Design Standards
The Ultravac 2100 is designed for sanitary conditions in USDA inspected facilities. All
UltraSource equipment is manufactured with respect to AMI Sanitary Design Standards. All
materials that are in food contact areas meet relevant USDA standards.
The Design and Technical Construction files for this machine are maintained at:
UltraSource LLC
1414 West 29th Street
Kansas City, MO 64108-3604 USA
Summary of Contents for ULTRAVAC 2100
Page 2: ......
Page 81: ......
Page 90: ...9 ...
Page 91: ...10 ...
Page 93: ...12 13 ...
Page 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Page 102: ...22 ...
Page 105: ......
Page 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...