Installation of Perforating Knives
CAUTION
CAUTION
Blade hazard.
Do not remove, install, or replace blades without protective gloves. Perforating knife blade is
sharp. Use care when handling.
Remove standard seal bars. Install perforating bars with the cutting blade facing toward
the outside of the lid. The use of air-assist is required for proper operation. The air-assist
regulator should be set at 20 to 30 p.s.i., not to exceed 40 p.s.i.
As the backup strip wears, it can be removed and changed end for end for a better surface.
The strip may also be turned upside down when one side is worn.
Installation of Precut Knives
CAUTION
CAUTION
Blade hazard.
Do not remove, install, or replace blades without protective gloves. Precut knife blade is sharp.
Use care when handling
Remove standard seal bars. Install precut seal bars with the blade facing toward the outside
of the lid. The use of air-assist is required for proper operation. The air-assist regulator
should be set at 20 to 30 p.s.i., not to exceed 40 p.s.i.
As the backup strip wears, it can be removed and changed end for end for a better surface.
The strip may also be turned upside down when one side is worn.
Figure 2.2
Precut Knife
this side
Excess Pouch
Summary of Contents for ULTRAVAC 2100
Page 2: ......
Page 81: ......
Page 90: ...9 ...
Page 91: ...10 ...
Page 93: ...12 13 ...
Page 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Page 102: ...22 ...
Page 105: ......
Page 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...