Remedy:
Install a condensate trap on the inlet of the
pump. Or, pump was overfilled with oil in oil reservoir.
Follow oil filling procedure (see Section 1.5) and do not
overfill. Or, the built-in anti-suck-back valve (Ref. 250
through 255) is leaking while pump was shut down and
vacuum was left in manifold. Clean the valve seat and
check that anti-suck-back valve holds vacuum on inlet
when pump is shut down.
4.8
Trouble
The automotive-type oil filter (Ref. 100) does
not get warm within two to five minutes
when cold pump is started.
Possible Cause:
The automotive-type oil filter is
clogged.
Remedy:
Replace the automotive-type filter per
Section 3.2 and exchange oil per Section 1.5.
Possible Cause:
The wrong automotive-type filter is
used and/or oil lines leading to pump are clogged.
Remedy:
Use only automotive filter as listed in
Section 3.2 and blow lines free
.
Flush oil cooler.
Possible Cause:
The oil cooler is plugged internally
with burnt oil.
Remedy:
Remove oil cooler and flush. Pump may
have to be disassembled completely to correct a
severely contaminated condition.
5.0
LIMITED STANDARD WARRANTY
Busch, Inc. warrants that all products furnished by it are
free from defects in material and workmanship at the
time of shipment for a period of 18 months from the
date of shipment, or 12 months from the date of instal-
lation, whichever occurs first. Claims must be made
during that period and are limited to the replacement or
repair of parts claimed to be defective.
In the case of components purchased by Busch, Inc.,
such as starters, controls, mechanical seals, motors,
couplings, etc., the warranty of that manufacturer will be
extended to the purchaser in lieu of any warranty by
Busch, Inc. The replacement of wear items including,
but not limited to, seals, bearings, couplings, exhaust
cover gaskets, oil drain plugs, oil fill plugs etc., made in
connection with normal service, are not covered by this
Warranty.
The Limited Standard Warranty is valid only when the
product has been properly installed, used in a normal
manner, and serviced according to the operating man-
ual. This warranty shall not extend to products that
have been misused, neglected, altered, or repaired
without factory authorization during the warranty period.
We highly recommend the use of Busch oils and parts
to achieve documented performance and efficient oper-
ation. The use of oils or parts other than Busch could
limit the life expectancy of the equipment and could void
any warranties if they are the cause of any damage.
Operating conditions beyond our control such as
improper voltage or water pressure, excessive ambient
temperatures, or other conditions that would affect the
performance or life of the product will also cause the
warranty to become void.
Permission to return parts for warranty repair must be
obtained, and all returns must be prepaid to the factory.
If, after examination, the product or part is found to be
defective, it will be repaired or replaced on a no-charge
basis and returned, FOB the factory. If it is determined
that the Warranty has not been breached by Busch,
Inc., then the usual charges for repair or replacement
will be made, FOB the factory. Parts or products that
are obsolete or those made to special order are not
returnable.
This Limited Standard Warranty applies only to the
above and is for the period set forth. Busch, Inc.'s max-
imum liability shall not, in any case, exceed the contract
price for the product, part, or component claimed to be
defective; and Busch, Inc. assumes no liability for any
special, indirect, or consequential damages arising
from defective equipment.
THERE ARE NO WARRANTIES IMPLIED OR
EXPRESSED THAT EXTEND BEYOND THOSE
CONTAINED IN THIS LIMITED STANDARD
WARRANTY.
Note:
For extended warranties on your new equipment
contact Busch Headquarters at 1-800-USA-PUMP.
12
Summary of Contents for ULTRAVAC 2100
Page 2: ......
Page 81: ......
Page 90: ...9 ...
Page 91: ...10 ...
Page 93: ...12 13 ...
Page 101: ...21 Maximum oil temperature with 80 F ambient temperature and no supplemental oil cooling ...
Page 102: ...22 ...
Page 105: ......
Page 120: ...RA 0165 0205 0255 0 0305 D Ref BMC Dwg T111 911 728 D 15 Fig 5 Exploded View Drawing of Pump ...