4.17
MAINTENANCE
Supervisor Menu with Touch Screen (continued)
Precut and Looping options
Prevac - 0-99% of vacuum before slits
are cut in the bag. Default 25%
Cut time - Amount of time allotted for
the cut cycle, 0.1 - 9 seconds Default 1.5
seconds
Wait time - Amount of time from Cut
cycle finish to Vacuum cycle startup
0.1 - 9 seconds, Default 4 seconds.
If the machine is equipped with the loop
option, this is the number of vacuum/
gas cycles the control will perform prior
to the seal and vent. The range is 1 to 5
cycles. The default is 1.
If the loop # is set to greater than 1,
the control can be set to exit the loop
on either the last gas cycle or the last
vacuum cycle prior to sealing.