Identifiers 

In  access  control  systems  each  user  has  a  unique  RF  ID.  Identifiers  can  take  the 
form of a plastic card, key FOB etc. 

Reader 

The  information  on  the  identifiers  is  read  with  READERS,  connected  to  the  ACS 
control panel. There are several types of RF IDs and readers for them. It is essential 
that  reader  and  control  panel  use  the  same  interface.  Only  U-Prox  series  readers 
may be connected to the U-Prox IP 100 control panel.  

PIN (Personal Identification Number) 

Some  readers  have  built-in  keypad.  Keypads  may  be  used  for  PIN  entering.  It  can 
be  both  self-dependant  or  used  as  an  additional  code  to  user  RF  ID. When  PIN  is 
programmed  as  additional  code,  reader  waits  for  PIN  entering  after  RF  ID  is  read-
out. 

Access point 

Access  point  is  a  logical  concept  of  the  access  control  system  implying  control  of 
passing  through  a  door  in  one  direction.  It  consists  of  reader, access  control  panel 
(or its part), door supervision devices (like  door contact, RTE button  etc.) and door 
locking  device.  For  instance,  the  turnstile  with  two-way  passes  has  two  Access 
points 

–  one  for  entrance  and  the  other  one  for  exit,  door  of  this  type  is  called 

double-sided  door.  A  door  with  a  reader  on  one  side  has  only  one  Access  point 

– 

Entry point, and it is called single-sided door\ 

Direction of passage 

Passageway - is a logical unit of ACS, controlling passage through the access point 
in  one  direction.  It  includes  reader,  access  control  panel  (or  part  of  access  control 
panel), actuator. So, tourniquet with double-sided control has two passageways, and 
the  door,  having  single-sided  reader  -  only  one  passageway.  Access  point,  which 
consists of two passageways, is called double-sided, and the point of access, which 
consists of one direction of passage - single- sided. 

RTE (request to exit) 

To exit from the premises with a single-sided door, a button wired to control panel is 
used.  This  button  is  called  RTE  (request  to  exit)  button.  If  someone  opens  a  door 
otherwise than pressing RTE button 

– by re-energizing locking device, opening lock 

with  a  key  etc.,  "Door  Forced  Open"  event  arises.  RTE  button  may  be  used  for 
remote door opening as well.  

Door Contact 

A properly designed ACS has to supervise door status (opened or closed): magnetic 
door  sensor,  sensor  of  the  turnstile  rotor  position,  inductive  sensor  of  the  road 
barrier,  etc.  This  ensured  that  the  system  prevents  situations  when  several  users 
access the door with one RF ID 

or door left open after user’s access and so on.  

Summary of Contents for IP100

Page 1: ...1 031 Access Control Panel U Prox IP100 Installation and programming manual...

Page 2: ...djustment of external devices and panel configuration are described in Working with the device section Technical support To get warranty and technical support you can apply to authorized service cente...

Page 3: ...th the device 20 Connection procedure 20 Installation recommendations 21 Installing Panel 21 Connecting an external reader 22 Connecting Loop Control 22 Request to Exit button RTE 23 Door Contact 23 C...

Page 4: ...r or two readers double sided door Having a large amount of non volatile memory U Prox IP100 is an access control system that provides for access control in variable establishments in small offices as...

Page 5: ...rvised inputs Built in Request to Exit button One relay contact NO NC COM 1 A 24 V One USB port to configure the network settings for connection to the ACS server Port Ethernet 4 wire 10 100 Mbps Wi F...

Page 6: ...oor of this type is called double sided door A door with a reader on one side has only one Access point Entry point and it is called single sided door Direction of passage Passageway is a logical unit...

Page 7: ...exit or tries to enter somewhere from the area he have not enter System generates message GLOBAL ANTIPASSBACK Access Denied in case of global antipassback violation Door time If door sensor is open c...

Page 8: ...Description and operation Panel The look of the access control panel is shown in Fig 1 and 2 Fig 1 U Prox IP100 panel Fig 2 U Prox IP100 components 3 4 2 1 1 Panel enclosure 2 RTE 3 LED 4 Keypad 7 1 1...

Page 9: ...X 4 RX Sound and light panel Yellow LED Standby mode periodic blinking o 1 short pulse once per second communication Working in notification mode connection normal o 2 short pulse once per second comm...

Page 10: ...is is the main mode of the panel In this mode the panel grants or denies access to RF ID owners In Normal mode the readers blink red Passing after entering RF ID To pass through user enters contactles...

Page 11: ...e of people such as in the case of fire earthquake or in other emergency For this case the panel has Free Pass mode In Free Pass Mode LED of reader flashes green and yellow The access point goes into...

Page 12: ...readers that have a built in keyboard Enter PIN code with the reader s keypad and press key Always enter PIN code AFTER the card pass If PIN code is correct panel unlocks access point and grants acces...

Page 13: ...is in Alarm Mode impulse the output is activated for the programmed time trigger mode on the first event the output is activated on the following is off etc continuous The communicator U Prox IP100 p...

Page 14: ...ra protection using VPN technology is recommend To provide backup communication channels use routers with two dissimilar channels of access to the Internet Working with multiple Wi Fi access points su...

Page 15: ...nsion of reserved IP if DHCP 5 Determine accessibility of ACS server and U Prox IC A control panel IP or DNS name 6 Periodic sending test signals 7 If there is send the events Waiting for server comma...

Page 16: ...ver and U Prox IC A control panel IP or DNS name 7 Periodic sending of test signals 8 If there is send the events Waiting for server commands 9 Failure transition to the second IP address of specified...

Page 17: ...rded into the DB Panel becomes associated to the certain access control system server eliminating panel control capture with another system Return panel to the factory settings to eliminate the panel...

Page 18: ...tion unspecified is assigned when registering a new employee or after the system operator command location reset of person is fixed by U Prox IC A With the use of global antipassback it is possible to...

Page 19: ...C F18 IP adjusting Only control panels with double sided doors entrance and exit on presentation of ID can be involved in global antipassback In configuraion server address 1 has to be the ACS server...

Page 20: ...s from sensors buttons 7 Run the cable lead Ethernet if necessary 8 Run the wire commutation of power supply lock reader inputs of the panel with the loops in accordance with the sections below recomm...

Page 21: ...st 20 cm from panel to eliminate the effect of double reading Installing Panel Loosen the screw at the bottom of panel Remove the upper lid remove the back plate Using the back plate of the panel as a...

Page 22: ...nsumption more than 100 mA supply the voltage to it from the separate source Connecting Loop Control Panel has two inputs for connecting the loops supervised with end of line resistors Each input func...

Page 23: ...Fig 15 Fig 15 Connection of RTE button Z1 input function assigned as follows Z1 RTE of access point A The use of button of the electric lock to open access point or allow access button on the turnsti...

Page 24: ...combined loop connection to Z1 terminals is on the Fig 17 Fig 17 Connecting combined loop Z1 input function assigned as follows Z1 Combined door contact and RTE of access point A Any of two inputs ca...

Page 25: ...or turns on and off any optional hardware with this output The example of actuator connection is on the Fig 19 The first is powering the lock and second by depowering Fig 19 Connecting locks When usi...

Page 26: ...erver Panel communicator operates in notification mode If there is event passage input violation data transmission to ACS server is initiated Panel provides protection against arbitrary interference d...

Page 27: ...nternet 2 optional o IP address of the DNS Server 1 if data transfer of the domain name is used o IP address of the DNS Server 2 optional if data transfer of the domain name is used Setting communicat...

Page 28: ...P address of the gateway router to the Internet 2 optional o IP address of the DNS server 1 if a data transfer of the domain name o IP address of the DNS Server 2 optional if you are using a data on t...

Page 29: ...refer to the software manual 4 Set up device with ACS software a Door settings Single sided or Double sided door operation of Antipassback Time of PIN entering or off b Access points settings no of re...

Page 30: ...qual to 0 zero 5 Upload write the new configuration to the panel The controller will restart with factory settings Switching to programming mode To put panel in programming mode do the following 1 Do...

Reviews: