It is recommended to use supplied resistors.
Request to Exit button (RTE)
RTE is used for exit through single-sided door. In this case, access point opens
when you press and release RTE. Use this input type for remote door opening
button connection also. For example, to open the door manually, by the secretary or
security guard.
Panel U-Prox IP100 has built-in RTE button, which can be activated or deactivated
during programming. The number of the loop of this button -
№ 3.
By default all inputs and build-in RTE button are off
The example of normally open contact RTE button connection to Z1 terminal is on
the Fig. 15.
Fig 15.
Connection of RTE button
Z1 input function assigned as follows:
Z1 - RTE of access point A
The use of button of the electric lock to open access point or "allow access"
button on the turnstile evokes the "DOOR FORCED OPEN" event
For proper operation, it is necessary to assign the connected loops as RTE when
programming.
Door Contact
Control panel supervises the door state or position of the turnstile rotor wit the door
contact. Panel cannot detect unauthorized access or door is open too long (multiple
entrance with one ID for instance) without the Door Contact.
The example of normally closed door contact connection to Z1 terminal is on the Fig.
16.
Fig 16.
Connecting door contact
Z1 input function assigned as follows:
Z1 - door contact of access point A
Access point, controlled by ACS, must have the door closer.