http://u-prox.com
11
attempt to re-pass when "Antipassback" is on (for 1 second buzzer is on
and LED is red)
entered RF ID is marked as lost or Blocking (for 1 second buzzer is on and
LED is red)
the panel is in "Alarm" mode (LED is constantly on and red)
the panel is in "Blocking" mode (LED flashes red and yellow in turn)
Pass count is exhausted for the temporary card (visitor).
"Alarm" Mode
In "Alarm" mode the reader indicator is constantly red. Depending on the
programmed functions Access point goes into mode
"Alarm"
in case of
unauthorized passage (Door Forced Open), opening of panel cover, entering RF ID
recorded as lost, if AP is open too long (open time AP is exceeded), and in case of
RF ID matching attempt.
In "Alarm” mode panel activates outputs, programmed as ALARM and SIREN.
"Alarm" output remains activated till “Alarm" mode is turned off. For output "SIREN",
siren time is programmable.
If Access point
is in “Alarm mode", passage is prohibited. Access point may be
opened by pressing RTE.
To exit from the "Alarm" mode pass the ID with "Disalarm" attribute or by command
from the computer.
"Free Pass
” Mode
There are circumstances when you need to open access points for free passage of
people, such as in the case of fire, earthquake or in other emergency. For this case,
the panel has "Free Pass" mode.
In "Free Pass
” Mode LED of reader flashes green and yellow.
The access point goes into "Free Pass" Mode after the command of operator from
the computer or after the loop violation (break or shortage) programmed as FREE
PASS. The access point is in "Free Pass" Mode for as long as the loop FREE PASS
is broken or until the command from the computer comes (while the loop is broken,
command from the computer will not work).
The panel allows to configure the function of loop "Free Pass" for access points A, B,
or for both access points (A + B).
As long as access point is in "Free Pass" mode, the lock is held in open position, the
panel stores a log event "Access granted" on presentation of RF ID code regardless
of the antipassback state of, schedules, etc. It is used to control the presence of
personnel on the premises in case of an emergency.
To ensure "Free Pass" mode when using locking devices with mechanical re-
platoon you must control access point state. Locking devices with mechanical re-
platoon can be unlocked with current pulse and remain unlocked until access point is
not opened. While closing door, locking device goes into a closed state. Panel in
"Free Pass" mode tests the door contact. Each closing of door again gives unlocking