409-10083
AMP 3K and AMP 5K Terminating Machines with the SL Starlite CQM
Rev E
15 of 38
Tyco Electronics Corporation
Figure 10
Guard
Open Icon
Green Indicator
Yellow
Indicator
Jog
Button
Speed Control
Knob
Fault Icon
Guard Disabled Icon
Machine Ready Icon
Speed Control Icon
Jog Button Icon
The green and yellow indicators on the top of the control panel indicate the machine status.
When the green indicator is on" and is not flashing, the machine is ready for operation.
When the green indicator is flashing by itself, a machine fault has been detected. When the green and
yellow indicators are flashing together, an SL Starlite monitor fault has been detected. See Figure 11.
To reset the machine, "power down" the machine, clear the problem area, and then "power up" the
machine; or hold down the footswitch until the indicators stops flashing.
When the yellow indicator is on and is not flashing, the guard is open and the machine will not run. (Note
that this will not occurr on the -18, -22, -24, and -25 machines.
When the yellow indicator is flashing but the green indicator is not, the guard is disabled and the machine will
only operate with the Jog button. An SL Starlite monitor fault has been detected when both indicators, green
and yellow, are flashing. See Figure 11. To reset the machine, "power down" the machine, clear the problem
area, and then "power up" the machine; or hold down the footswitch until the indicators stops flashing.
The Jog button icon indicates intermittent operation at a slower speed when using the Jog button.
The Jog button allows the operator to cycle through various stages of the machine cycle.
The Speed Control Knob determines the machine speed (active in both normal operation and Jog operation)
Speed increases as the knob is turned CLOCKWISE.
Speed Ranges:
From 100% to 60% with the foot pedal
From 60% to 25% with the Jog button
Optional Batch
Counter
3K/40
The speed control knob also adjusts the air feed timing. Normally, the air feed timing is set at 280 ms. When
the speed control is set at less than 50% of its maximum setting (pointing straight down or counterclockwise
from pointing straight down), the air feed timing changes to 440 ms. This is done to accommodate applicators
that have longer than normal air cylinders.