7. ADJUSTMENTS
The following adjustments are necessary to maintain the machine in operating condition, and to set up the
machine after replacing parts.
To avoid personal injury, ALWAYS disconnect electrical and air supplies before performing adjustments.
7.1. Measuring the Shut Height
The shut height is the distance between the bottom surface of the ram post adaptor and the top surface of the
machine base plate as shown in Figure 13.
Shut Height Gage 679655-[ ] (see the table in Figure 13) is recommended for measuring shut height (refer to
408-8535 for instructions on use of the gage).
1. Turn off the machine using the power switch on the back panel.
2. If installed, adjust the manual precision adjustment lever to the “0” setting.
3. Remove the access cover (Figure 7) on the end of the motor.
4. Insert a 6–mm hex wrench into the end of the motor until it completely engages the hex key in the
end of the motor. Use the hex wrench to manually rotate the motor.
To aviod personal injury, always be sure to turn off the power to the machine when manually cycling. Be sure to
remove the hex wrench and replace the access cover before turning on power to the machine.