409-10083
AMP 3K andAMP 5K Terminating Machines with the SL Starlite CQM
Rev E
35 of 38
Tyco Electronics Corporation
8.4. Installation of Air FeedKit 1424266-1
To avoid personal injury, be sure to turn off" the machines, and disconnect them from the power source.
1. Remove the four bolts securing the rear controller panel to the frame. Refer to Figure 28.
2. Remove the control panel from the machine and pivot it in order to view the control board.
3. Insert the small end of the air feed cable assembly (see Customer Drawing 1424266) into the J7
socket. See Detail in Figure 28.
4. Install the control panel into the machine with the air feed cable assembly through the upper right
hand slot in the machine frame. See Figure 28.
5. Remove the two bolts securing the rear of the left sheet metal guard. See Figure 28.
6. Install Air Feed Bracket 1338977–1 to the frame (see Figure 29) using the two bolts securing the
sheet metal guard (Figure 28).
7. Prepare the baseplate assembly as follows:
a. For Air Feed Kit 1424266–1 (standard machine base plate), install the socket head screw and rear
stop to the baseplate as shown in Figure 30. Then remove the back left baseplate clamp.
b. For Air Feed Kit 1424266–2 (universal machine base plate), install the socket head cap screw (as
shown in Figure 31) and Air Feed Clamp 1338963–1. Then remove the back left baseplate clamp.
8. Install the air feed applicator onto the baseplate.
9. Connect the air lines to the applicable ports, as shown in Figure 28.
10. Turn the air “on” by moving the slide valve (Figure 29)
toward the filter.
The air can be turned off "by moving the slide valve away from the filter.
11. Lock the air in the “off” position. Turn the air “off” and clamp the valve lockout in position as shown in
Figure 28.
DANGER
NOTE
i