409-10083
AMP 3K and AMP 5K Terminating Machines with the SL Starlite CQM
Rev E
28 of 38
Tyco Electronics Corporation
8. Attach the light (as shown in Figure 16, Detail A) to the top of the user interface enclosure using the
socket screws provided.
9. If equipped with Batch Counter Kit 1424267–1, insert the batch counter kit into the appropriate
knockout opening until it snaps into place. The red reset button should be on the right–hand side.
10. Re–attach the connector from the machine wiring harness to the J1 connector on the pc board in the
interface assembly.
11. Install the user interface assembly into the frame and secure using the two socket head screws.
Be sure the interface assembly wiring harness is not pinched or kinked.
12. Close the clear guard on the machine.
13. Connect the machine to the power source and turn the machine “on.”
8.2. Installation of Work Light Assembly Kit 1424264-1 (Inside the Guard)
Typically, when this assembly is mounted, it is mounted
outside the guard. (See Figure 17.) This procedure
allows you to install the work light kit
inside the guard.
Figure 17
To avoid personal injury, be sure to turn off" the machine and disconnect it from the power source.
CAUTION
!
DANGER