409-10083
AMP 3K and AMP 5K Terminating Machines with the SL Starlite CQM
Rev E
26 of 38
Tyco Electronics Corporation
218.
MACHINE OPTIONS AND INSTALLATION
The following machine options are available for the AMP 3K and AMP 5K machines:
PART NUMBER
DESCRIPTION
PURPOSE
1424264-1
Work Light Kit (64111 Osram/Sylvania)
Provides lighting to the work area
1424266-1
Air Feed Valve Kit with 40-mm [1
5
/
8
-in.] Stroke
Required to run 40-mm [1
5
/
8
-in.] stroke applicators
1424266-2
Air Feed Valve Kit with 30-mm [1
1
/
8
-in.] Stroke
Required to run 30-mm [1
1
/
8
-in.] stroke applicators
1424267-1
Batch Counter Kit
Counts terminations
1424208-1
Precision Adjust Field Retrofit Kit
Allows 0.0127-mm [.0005-in.] adjustments
354550-3
Lubricator Bowl Assembly
Pre-lubricates the strip
1428156-1
Shoulder Eye Bolt
Provides a lift point for machine installation
In addition to the previously listed options, the following machine options are available
only for Machines –17
and –18:
JAM Applicator Mounting Kit 1424268–1
JST Applicator Mounting Kit 1424269–1
8.1. Installation of Work Light Assembly Kit 1424264-1
To avoid personal injury, be sure to turn off" the machines and disconnect them from the power source.
1. Open the clear guard on the machine to gain access to the two socket head screws securing the user
interface to the frame.
2. Remove the two socket head cap screws securing the user interface to the frame. Carefully lift the
user interface assembly to clear the sheet metal guard.
Use caution when removing the interface so that the wiring harness to the interface is not damaged.
3. If equipped with Batch Counter Kit 1424267–1, depress the tabs on the side of the batch counter
within the user interface assembly and pull the batch counter out of the enclosure.
Do not pull or damage the wiring harness to the batch counter.
4. Disconnect the user interface assembly wiring harness connector from the printed circuit (pc) board
inside the user interface assembly.
DANGER
CAUTION
!
CAUTION
!