409-10083
AMP 3K and AMP 5K Terminating Machines with the SL Starlite CQM
Rev E
25 of38
Tyco Electronics Corporation
Standard Guard Insert
Tape Guard Insert
A"
B"
GUARD INSERT
DIMENSION
PART NUMBER
DESCRIPTION
A
B
354529-2
Standard (Away from the Applicator)
7.80 [.307]
6.35 [.250]
1-679532-0
Standard (Close to the Applicator) Ċ
Shipped with the Machine
6.22 [.245]
5.08 [.200]
679994-2
Near Tape
6.35 [.250]
6.35 [.250]
679995-2
Away from Tape
8.74 [.344]
6.35 [.250]
Figure 15
A. Guard Insert 1-679532-0 and Guard Insert 679994-2
1. Slide the insert into the rear slot of the guard door. Secure the insert to the door with two screws
placed through the large square holes in the left guard door and into the threaded holes in the top of the
insert. Do
not tighten the screws.
2. Move the insert horizontally and vertically as needed to align the slot with the crimp area of applicator.
3. Tighten the screws.
B. Guard Insert 354529-2 and Guard Insert 679995-2
1. Slide the insert into the front slot of the guard door. Secure the insert to the door with two screws
placed through the large square holes of the insert and into the threaded holes in the bottom of the left
guard door. Do
not tighten the screws.
2. Move the insert horizontally and vertically as needed to align slot with crimp area of the applicator.
3. Tighten the screws.