Commissioning
Testing read/write heads with the DTM
58
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
7.3.4
RFID Test – Basic test window
Fig. 52: RFID Test – Basic test window
The following functions are available in the
Basic test
window:
Icon
Function
Description
Polling
Shows the first tag in the polling memory of the device in the
tag list. The function is only available in polling mode.
Poll all
Shows all tags in the polling memory of the device in the tag
list. The function is only available in polling mode.
Clear polled tags from read/write
head
Clears the polling memory of the read/write head.
Group tag list
Combines readings of tags with the same EPC.
CSV export current values
Saves the tag list in CSV format.
Clear tag list
Deletes the list of displayed tags.
The queried data is displayed in the tag list. The content of the message can be set via the
Configure message content
function.
NOTE
If the polling memory of the read/write head is full, the ERR LED is lit red and
indicates an internal error.