Setting
RFID channels – process output data
154
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
8.3
RFID channels – process output data
Process output data – UHF compact mode
Byte no.
Bit
PROFINET Modbus
EtherNet/
IP
7
6
5
4
3
2
1
0
0
0
Command code (CMDC)
1
1
2
2
Loop counter for rapid processing (RCNT)
3
3
Memory area (DOM)
4
4
Start address (ADDR)
5
5
6
6
7
7
8
8
Length (LEN)
9
9
10
10
Length of EPC (SOUID)
11
11
Reserved
12
24
Write data Byte 0
13
25
Write data Byte 1
14
26
Write data Byte 2
15
27
Write data Byte 3
16
28
Write data Byte 4
17
29
Write data Byte 5
18
30
Write data Byte 6
19
31
Write data Byte 7
…
…
…
131
151
Write data Byte 127