Setting
RFID channels – overview of the commands
192
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
8.5.21
Command: Reset
The
Reset
command resets the read/write head and interface.
Request
Loop counter
See description of the output data, [
Command code
0x8000 (hex.), 32768 (dec.)
Read/write head address
See description of the output data, [
Length UID/EPC
Not required
Start address
0: Software reset
1: Voltage reset
Length
Not required
Command timeout
See description of the output data, [
Write fragment no.
0
Read fragment no.
See description of the output data, [
Write data
Not required
Response
Loop counter
See description of the input data, [
Response code
0x8000 (hex.), 32768 (dec.)
Length
Not required
Error code
See description of the input data, [
Tag within the
detection range
See description of the input data, [
Data (bytes) available
See description of the input data, [
Tag counter
See description of the input data, [
Write fragment no.
0
Read fragment no.
See description of the input data, [
Read data
Not required