Commissioning
Parameterizing read/write heads with the DTM
42
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
At
Antenna configuration
Ò
Maximal transmit time
set the time up to the polarization
switch or activate the
Switch to next antenna if no transponder was read
option.
a
If the
Switch to next antenna if no transponder was read
option is enabled, the read/
write head automatically switches after an Inventory operation without reading to the
next multiplex sequence (
Entry
).
Fig. 36: Switching polarization automatically