V02.00 | 2020/08
183
8.5.16
Command: Tag info
NOTE
The command code for fast processing with the loop counter is 0x2050 (hex.) or
8272 (dec.).
The
Tag info
command enables the following chip information of a tag to be scanned:
n
Allocation class identifier
n
Tag mask designer identifier
n
Tag model number
The data is queried from the GSI record of the tag.
Request
Loop counter
See description of the output data, [
Command code
0x0050 (hex.), 80 (dec.)
Read/write head address
See description of the output data, [
Length of EPC
Not required
Start address
Start address in the GSI record
Length
Length of the system data read (bytes)
0: All system data is read
Command timeout
Not required
Write fragment no.
Not required
Read fragment no.
See description of the output data, [
Write data
Not required
Response
Loop counter
See description of the input data, [
Response code
0x0050 (hex.), 80 (dec.)
Length
See description of the input data, [
Error code
See description of the input data, [
Tag within the detection range
See description of the input data, [
Data (bytes) available
See description of the input data, [
Tag counter
See description of the input data, [
Write fragment no.
0
Read fragment no.
See description of the input data, [
Read data, Byte 0...3
First 32 bytes of the TID (tag class, manufacturer and chip
type)
Read data, Bytes 4…n
EPC (length variable)
Summary of Contents for TN-UHF AUS-CDS Series
Page 1: ...Your Global Automation Partner Instructions for Use TN UHF CDS UHF Read Write Head ...
Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...
Page 97: ...V02 00 2020 08 97 Transfer the mapping to the POU Fig 94 Transferring the mapping to the POU ...