Setting
RFID channels – process input data
150
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
8.2
RFID channels – process input data
Process input data – UHF compact mode
Byte no.
Bit
PROFINET Modbus
EtherNet/
IP
7
6
5
4
3
2
1
0
0
0
Response code (RESCUHF)
1
1
2
2
Loop counter for rapid processing (RCNT)
3
3
Reserved
4
4
TRE1
PNS1
TP1
5
5
CMON
6
6
Length (LEN)
7
7
8
8
Error code (ERRC)
9
9
10
10
Tag counter (TCNT)
11
11
12
16
Reserved
13
17
Reserved
14
18
Reserved
15
19
Reserved
16
20
Reserved
17
21
Reserved
18
22
Reserved
19
23
Reserved
20
24
Read data Byte 0
…
…
…
147
151
Read data Byte 127