Setting
RFID channels – overview of the commands
174
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
8.5.9
Command: End Continuous (presence sensing) mode
Continuous and presence sensing mode can be stopped via the
Shut down Continuous (pres-
ence sensing) mode
command. The data in the buffer of the interface is not deleted after the
command is executed and can still be called up by the controller via the
Get data from buffer
command.
Request
Loop counter
See description of the output data, [
Command code
0x0012 (hex.), 18 (dec.)
Read/write head address
Not required
Length of EPC
Not required
Start address
Not required
Length
Not required
Command timeout
See description of the output data, [
Write fragment no.
0
Read fragment no.
See description of the output data, [
Write data
Not required
Response
Loop counter
See description of the input data, [
Response code
0x0012 (hex.), 18 (dec.)
Length
Not required
Error code
See description of the input data, [
Tag within the
detection range
See description of the input data, [
Data (bytes) available
See description of the input data, [
Tag counter
See description of the input data, [
Write fragment no.
0
Read fragment no.
See description of the input data, [
Read data
Not required