Commissioning
Parameterizing read/write heads with the DTM
30
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
7.1.5
Setting multiplex operation
In multiplex operation, several antennas can be controlled or switched on in sequence. The
example below shows the activation of the antennas in sequence. The multiplex operation can
consist of up to 16 sequences and can be used, for example, for gate applications.
Fig. 21: Gate application – schematic representation
Configuring multiplex operation – example
Choose the
Antenna
tab in the main menu.
At
Antenna
Ò
Antenna multiplexing
Ò
Number of entries
enter the number of anten-
nas.
Fig. 22: Entering the number of antennas