background image

SL-VTPR□

Relay Output Terminal

Flexible Wire-saving Link System 

S-LINK V

INSTRUCTION MANUAL

MJE-SLVTPR No.0063-19V

Thank you very much for purchasing Panasonic products. Read this Instruc-

tion Manual carefully and thoroughly for the correct and optimum use of this 

product. Kindly keep this manual in a convenient place for quick reference.

 

● Never use this product in a device for personnel protection.

 

● In case of using devices for personnel protection, use products which 

meet laws and standards, such as OSHA, ANSI or IEC etc., for person-

nel protection applicable in each region or country.

 

● Before touching this product, remove any electrostatic charge that may 

be present on your body. There is a danger of this product getting dam-

aged due to the electrostatic charge.

Please refer to the "

S-LINK V User's Manual

" for details of the entire 

S-LINK V

 system.

PARTS NAMES AND FUNCTIONS

1

SL-VTPR4

SL-VTPR8

1
2
3
4
6

8

7

5

4-core flat cable, 0.6m long

8

7

5

1
2
3
4
6

4-core flat cable, 0.6m long

Designation

Function

1 Address setting switches Used for setting of the terminal address.

2 Output holding function

setting switch

Used for setting of the output holding function.

ON: Hold the current output conditions (output holding).

OFF: Will not hold the current output conditions (output OFF).

3 Power indicator (Green)

This indicator will light when the power is supplied.

4 Transmission indicator

(Green)

This indicator will blink when the synchronization 

signal is sent from the 

S-LINK V

 controller.

5 Operation indicator

(Orange)

Lights when each output relay is turned ON.

6 Relay remover key

Use this key to remove the output relays.

7 Output relay

PA-N relay APAN3124 manufactured by Panasonic 

 

Co., Ltd. (Note)

8 Terminal block

Used for connection of output devices.

Note:  You can replace the output relays.

 

For a detailed description, refer to “

RELAY REPLACEMENT

.”

MOUNTING

2

<In case of mounting on DIN rail>

Mounting method

1. Push the DIN rail stopper inside.

2. Fit the tab on the opposite side of the 

DIN rail stopper into the 35mm width 

DIN rail.

3. Press down the tab on the other side 

against the 35mm width DIN rail to fit it.

DIN rail stopper

35mm width DIN rail

1

3

2

Removing method

1. Insert a flathead screwdriver to the 

groove on the DIN rail stopper and pull 

out the stopper.

2. Push the product to the other side of 

the DIN rail stopper.

3. While maintaining the condition in the 

procedure 2, and lift up the product to 

remove it.

Flathead screwdriver

DIN rail stopper

Note:  Take care that if the product is lifted with the stopper remained inside, the tabs crack.

OUTPUT CIRCUIT DIAGRAM (per channel)

3

S-LINK V

 system side

Internal circuit

Output device side

Main circuit

Output relay

+24V

D

G

0V

Output

SL-VTPR4

: Output 0 to 3

SL-VTPR8

: Output 0 to 7

 

Terminal arrangement diagram

SL-VTPR4

SL-VTPR8

Upper side
Lower side

Output 0

Output 2

Output 1

Output 3

Terminal

No.

DIN rail stopper

Upper side
Lower side

Output 0

Output 5

Output 3

Output 7

Output 6

Output 4

Output 2

Output 8

Terminal

No.

DIN rail stopper

Output

Output 0

Output 1

Output 2

Output 3

Terminal

No.

5

6

7

8

1

2

3

4

Output

Output 0

Output 1

Output 2

Output 3

Output 4

Output 5

Output 6

Output 7

Terminal

No.

9 10 11 12 13 14 15 16
1

2

3

4

5

6

7

8

Cover

M4 pan head screw

Please arrange 

separately

<In case of mounting with screws>

 

● In case of mounting with screws, use 

M4 pan-head screws and the tighten-

ing torque should be 0.8N·m or less.

W

59.2mm

Model No.

W

SL-VTPR4

47.5mm

SL-VTPR8

78mm

Dimensions for mounting holes

SL-VTPR8 

+ AQZ202D

4.00

3.00

2.00

1.00

0

-

20

0

20

40

60

Ambient

temperature (°C)

Load current (A)

No. of output-ON relay pts.: 1 or 2

No. of output-ON relay pts.: 7 or 8

No. of output-ON relay pts.: 3 or 4

No. of output-ON relay pts.: 5 or 6

Ambient

temperature (°C)

SL-VTPR8 

+ AQZ204D

0.40

0.30

0.20

0.10

0

-

20

0

20

40

60

Load current (A)

No. of output-ON relay pts.: 7 or 8

No. of output-ON relay pts.: 1 or 2

No. of output-ON relay pts.: 3 or 4

No. of output-ON relay pts.: 5 or 6

Ambient

temperature (°C)

SL-VTPR8 

+ AQZ205D

2.00

1.50

1.00

0.50

0

-

20

0

20

40

60

Load current (A)

No. of output-ON relay pts.: 7 or 8

No. of output-ON relay pts.: 1 or 2

No. of output-ON relay pts.: 3 or 4

No. of output-ON relay pts.: 5 or 6

Ambient

temperature (°C)

SL-VTPR8 

+ AQZ207D

0.80

0.60

0.40

0.20

0

-

20

0

20

40

60

Load current (A)

No. of output-ON relay pts.: 7 or 8

No. of output-ON relay pts.: 1 or 2

No. of output-ON relay pts.: 3 or 4

No. of output-ON relay pts.: 5 or 6

 

● In case of using PA-N relay (APAN3124), use this product in the ambient 

temperature range of -10 to +55° and with 3A output current. 

 

● In case of using PhotoMOS relay (AQZ20□D), the output current is 

restricted depending on ambient temperature and the number of Photo-

MOS relay ON points.

Ambient temperature and number of PhotoMOS relay ON points - 

Load current characteristics

 

● The upper limit value of the load current depends on the ambient tem-

perature and the number of PhotoMOS relay ON points.

Reviews: