20
TRI93.134.5
www.tritium.com.au
Veefil®isaregisteredtrademarkofTritiumPtyLtd.©2015TritiumPtyLtd
6b. Fit above ground conduit & feed
in power
Remove the blanking plug and replace
with supplied conduit fitting and seal.
Feed the conduit from the rear right of
the unit and bend up into the conduit
fitting. Remove the radiator if required.
(see Unpacking and Installation).
415V 3PH
Copper Conductors Only
N
x
Trim the conduit to fit into the conduit
fitting and feed a minimum of 300mm/12
inches of wiring through into the interior
ready for commissioning. Seal the con-
duit into the conduit fitting with Jointing
Cement so that no water or debris can
enter.
Use the slots in the rear left channel to
cable tie the conduit in place if necessary.
6a. Fit underground conduit & feed
in power
If your installation has above ground
conduit, see 6b.
Remove the blanking plug and replace
with supplied conduit fitting and seal.
Trim the conduit to fit into the conduit
fitting and feed a minimum of 300mm/12
inches of wiring through into the interior
ready for commissioning. Seal the con-
duit into the conduit fitting with Jointing
Cement so that no water or debris can
enter.
415V 3PH
Copper Conductors Only
N
x
Fix to ground and feed power
Fix to ground and feed power