TrimTrac ProE Locator Technical Manual v2.0e
48
When the device is to be
queried for its current
position, send it a
QUERY_POSITION
message with Position
Query Mode set
“P=Compute New Position”
Upon receipt of the
QUERY_POSITION
message, the device will
compute a new position fix
regardless of how the
Position Age flag is set.
The device may not receive
the QUERY_POSITION
message until Polling Duty-
Cycle Frequency, T19
expires (up to an one-hour
in this example), the next
Scheduled Report time, or
upon expiration of the IDLE
Timeout, T1, whichever is
earliest.
Table 14, Minimize Communication Costs and Query-to-Fix
Query-to-Fix Configuration with Weekly status
messages at Sunday 12:00AM UTC and hourly
polling.
See
Page
AT+CTKC=43200,300,300,900,60,168,20,0,1,1,0 126
AT+CTKX=
1
,0,0,
1
,3600,60,0,0,1,1,10,20,10,
2
127
Table 15, Sample Non-default Commands for Query-to-Fix Configuration
Summary of Contents for ProE Locator
Page 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Page 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Page 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Page 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Page 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Page 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Page 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...