TrimTrac ProE Locator Technical Manual v2.0e
101
ii.
If
Position Age
is set “0=Current”, then go to the IDLE state
upon expiration of MPA Delay Timeout, T14.
c.
“3=Acknowledged”, then go to the IDLE state upon expiration of
DELAY Timeout, T4
.
7.
Proceed immediately to the IDLE state whenever:
a.
The LPA switch is in its “armed” closed position regardless of how
the LPA Status is set.
b.
LPA Status is set “1=Activated” regardless of the LPA switch
position (“unarmed” open or “armed” closed).
8.
All Delay Timeouts (T4, T13 and T14) are immediately terminated
whenever any alert status state (
HPA Status
, MPA Status or
LPA Status
) is
or becomes set to “1=Activated” and the unit immediately transitions to
the IDLE state.