TrimTrac ProE Locator Technical Manual v2.0e
99
b.
“2=Sent”, then ignore all data messages received prior to the
receipt of SET_ALERT_STATE message and:
i.
If
Position Age
is set “1=Aged”, then go immediately to the
IDLE state; or
ii.
If
Position Age
is set “0=Current”, then go to the IDLE state
upon expiration of HPA Query Timeout, T17.
2.
If
MPA
Status is set:
a.
“1=Activated”, then go to immediately to the IDLE state;
b.
“2=Sent” then ignore all data messages received prior to the receipt
of SET_ALERT_STATE message and go immediately to the
IDLE state.
3.
If LPA Status is set:
a.
“1=Activated”, then go to immediately to the IDLE state;
b.
“2=Sent” then ignore all data messages received prior to the receipt
of SET_ALERT_STATE message and go immediately to the
IDLE state.
4.
During the QUERY state, any alert (High, Low, Medium) status can be
changed from “2=Sent” or “3=Acknowledged” to “0=Clear”,
“3=Acknowledged”, or “X=Do not care” upon receipt of the appropriately
configured SET_ALERT_STATE message.
Summary of Contents for ProE Locator
Page 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Page 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Page 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Page 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Page 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Page 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Page 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...