TrimTrac ProE Locator Technical Manual v2.0e
150
SET_EXT_APP_CONFIG
This message is used to set the Extended Application parameters in the TrimTrac
ProE. When received the TrimTrac ProE will send a RESP_EXT_APP_CONFIG
(page 171) message in response.
>STKABCCCCCCDEFFFFFFGGGGGGHIJJJKKKLLMMNNO;PW=PPPPPPPP;
ID=YYYYYYYY;*ZZ<
A
TrimTrac Configuration Set
: ‘X’ = Extended Application
Parameters
B
Scheduled Report
Mode
. 0=None; 1=Daily; 2=Weekly. Default
0
CCCCCC
Scheduled Report Time,
T18
. In Seconds (0-604799).
Note: This
is either the seconds into the day or into the week for the device to
schedule transmission of a STATUS_MESSAGE plus the most
recently logged
POSITION_REP, if any, when this feature is enabled.
If Scheduled
Report Mode
is set “0=None”, then enter 0. Default
0
.
D
In-Motion Polling.
0=Disabled; 1=OnDemand while in Motion. Note:
If set to “1=OnDemand while in Motion”, the unit is able to receive
and process data messages
ONLY while in motion regardless of
current state.
Default
0
E
Anytime Polling.
0=Disabled; 1=Duty-Cycled while in IDLE
State; 2=Anytime OnDemand. See “Polling” section on page 39.
Note: If set to “2=Anytime OnDemand”, the unit is able to
receive and process data messages regardless of motion, current
state or how In-Motion Polling is set. If set “1=Duty-Cycled”,
unit is able to receive and process data messages while in
QUERY or whenever while Polling Duty-Cycle On-Time, T20,
is running.
. Default
0
. Note: In-Motion Polling is treated as always
“1=Enabled” when Anytime Polling is set to “2=Anytime
OnDemand”.
FFFFFF
Polling Duty-Cycle Frequency,
T19
.
In Seconds (10-999990).
Note: Determines how frequently the Polling Duty-Cycle On-Time,
T20, timer is started if and only if the Anytime Polling is set
to
“1=Duty-Cycled while in
IDLE State”
and device is NOT in
motion.
Default
3600
.
GGGGGG
Polling Duty-Cycle On-Time,
T20
.
In Seconds (0,
10-999990).
Note: Determines how long after expiration of Polling Duty-Cycle
Frequency, T19, timer that
the unit is able to
receive and process data
messages. A value of zero
causes
the QUERY Timeout, T5, value to
be used.
Default
60
.
H
Query Hold Flag.
0=Disabled; 1=Enabled.
Note: Unit attempts to
reconnect to the GSM network if the connection is lost during the
QUERY state prior to the expiration of QUERY Timeout,
T5.
Default
0
.
I
Reserved.
0=Formerly “Extended
Motion Detection” in
TrimTrac
1.0 Not used in TrimTrac ProE.
Default
0
.
Summary of Contents for ProE Locator
Page 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Page 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Page 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Page 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Page 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Page 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Page 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...