TrimTrac ProE Locator Technical Manual v2.0e
196
Geofence Settings:
Parameter
Unit/Notes
Default
Messages Commands
Geofence ID
Unique geofence identifier 1 or 2
1
Geofence Enforcement
0=Disabled; 1=Enforced; 2=LPA Input Enforced; 3=LPA
Centered and Enforced.
0
Geofence Schedule
0=24/7; 1=After Scheduled Hours; 2= During Scheduled
Hours. (See Scheduled Hours Mode)
0
Geofence Delta X
100s of meters (1 – 10000) Note: East-West length of
rectangular Geofence area or, if circular, the diameter.
1=100 Meters
1
Geofence Delta Y
100s of meters (0, 1 – 10000) Note: If set to “0”, then
circular Geofence area; else rectangular Geofence area.
1=100 Meters
1
Geofence Center Latitude WGS-84 Coordinates. Units of Degrees to 7 decimal
places plus ‘+’ sign = North and ‘-‘ = South.
(-90.0000000 to +90.0000000)
+0.0000000
Geofence Center
Longitude
WGS-84 Coordinates. Units of Degrees to 7 decimal
places plus ‘+’ sign = East and ‘-‘ = West.
(-180.0000000 to +180.0000000)
+0.0000000
>STKK
>QTKK
>RTKK
AT+CTKK
Geofence Type
0=Boundary Crossing; 1=Inclusive; 2=Exclusive
1
>STKZ
AT+CTKZ
Table 97, Geofence Settings.
Summary of Contents for ProE Locator
Page 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Page 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Page 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Page 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Page 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Page 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Page 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...