TrimTrac ProE Locator Technical Manual v2.0e
117
AT+CTKC Application Configuration
The AT+CTKC command is used to configure the Basic Read/Write parameters
of the TrimTrac ProE. It can query the current settings or change them to new
values.
AT+CTKC=<
IDLE Timeout, T1
>,<
FIX Timeout, T2
>,<
TRANSMIT Timeout,
T3
>,<
DELAY Timeout, T4
>,<
QUERY Timeout, T5
>,<
Almanac Timeout,
T6
>,<
Static Motion Filter Timeout, T7
>,<
Motion Report Flag
>,<
Report Delay
Flag
>,<
Diagnostics Mode
>,<
Communication Mode
>
OK
<IDLE Timeout,
T1
>
In seconds (10 – 999990). Default
43200
<FIX Timeout,
T2
>
In seconds (10 – 3600). Default
300
<TRANSMIT Timeout,
T3
>
In seconds (10 – 3600)
Less than 300 not
recommended
. Default
300
<DELAY Timeout,
T4
>
In seconds (10 – 86400). Default
900
<QUERY Timeout,
T5
>
In seconds (10 – 3600). Default
60
<Almanac Timeout,
T6
>
In hours (10 – 990). Default
168
<Static Motion
Filter
Timeout, T7
>
In seconds (0 – 90). Note: T7 is used exclusively
while
in the IDLE
state;
however, it is superseded
by the
Dynamic Motion Filter
Timeout, T21, whenever
Anytime Polling is:
A.
Set “2=Anytime OnDemand”;
OR
B.
Set “1-Duty-Cycled” and Polling Duty-Cycle On-
Time, T20, is running.
Always
set Static Motion Filter Timeout, T7, greater
than or equal to Static Motion Filter Counter, N3.
Default
20
<Motion Report Flag>
0=None
1=Start Motion Report
2=Stop Motion Report
3=
Start & Stop Motion Reports
. Default
0
<Report Delay Flag>
0=Transmit (“Tx”) All Messages
1=Tx Exception Reports & Query/Set
Responses only
2=Tx Motion-related, Exceptions &
Responses
3=Tx IDLE Timeout, T1,
Status Msgs, Exceptions
&
Responses
4=Tx Start/Stop, IDLE
Status, Exceptions & Responses
5=Tx every 6th motion-triggered message, Exceptions &
Respones
6=Tx every 11th motion-triggered message, Exceptions &
Respones
7=Tx Start/Stop, Exception & Responses (No IDLE
Status). Default
0
<Diagnostics Mode>
0= None; 1= LED. Default
1
<Communication Mode>
0= SMS; 1= GPRS; 2=AutoSelect. Default
0
Table 29, AT+CTKC Assignment
Summary of Contents for ProE Locator
Page 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Page 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Page 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Page 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Page 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Page 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Page 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...