AT+CTKX Extended Application Configuration
The AT+CTKX command is used to configure the enhanced Basic Read/Write
parameters of the TrimTrac ProE. It can query the current settings or change
them to new values.
AT+CTKX=<Scheduled Report Mode>,<Scheduled Report Time, T18>,<In-
Motion Polling>,<Anytime Polling>,<Polling Duty-Cycle Frequency,
T19>,<Polling Duty-Cycle On-Time, T20>,<Query Hold
Flag>,<Reserved>,<Position Report Transmit Attempts, N1>,<Status Message
Transmit Attempts, N2>,<Static Motion Filter Counter, N3>,<Dynamic Motion
Filter Timeout, T21>,<Dynamic Motion Filter Counter, N4>,<Motion Sensor
Override>
OK
<Scheduled Report
Mode
>
0=None; 1=Daily; 2=Weekly. Default
0
<Scheduled Report Time,
T18
>
In Seconds (0-604799).
Note: This is either the seconds
into the day or into the week for the device to schedule
transmission of a STATUS_MESSAGE plus the most
recently logged
POSITION_REP, if any, when this feature
is enabled. If Scheduled
Report Mode
is set “0=None”,
then enter 0. Default
0
<In-Motion Polling>
0=Disabled; 1=OnDemand while in Motion. Note: If set to
“1=OnDemand while in Motion”, the unit is able to receive
and process data messages
ONLY while in motion
regardless of current state.
Default
0
<Anytime Polling>
0=Disabled; 1=Duty-Cycled while
in IDLE State;
2=Anytime OnDemand. See “Polling” section on page
39. Note: If set to “2=Anytime OnDemand”, the unit is
able to receive and process data messages regardless of
motion, current state or how In-Motion Polling is set.
If set “1=Duty-Cycled”, unit is able to receive and
process data messages while in QUERY or whenever
while Polling Duty-Cycle On-Time, T20, is running.
.
Default
0
<Polling Duty-Cycle
Frequency,
T19
>
In Seconds (10-999990).
Note: Determines how frequently
the Polling Duty-Cycle On-Time, T20, timer is started if and
only if the Anytime Polling is set
to “1=Duty-Cycled
while in
IDLE State”
and device is NOT in motion.
Default
3600
<Polling Duty-Cycle On-
Time,
T20
>
In Seconds (0,
10-999990).
Note: Determines how long
after expiration of Polling Duty-Cycle Frequency, T19,
timer that
the unit is able to
receive and process data
messages. A value of zero
causes
the QUERY Timeout,
T5, value to
be used.
Default
60
<Query Hold Flag>
0=Disabled; 1=Enabled.
Note: Unit attempts to reconnect to
the GSM network if the connection is lost during the
Summary of Contents for ProE Locator
Page 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Page 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Page 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Page 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Page 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Page 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Page 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...