TrimTrac ProE Locator Technical Manual v2.0e
149
SET_CONTROL_OUTPUT
This message is sent by the server to set the Control Module Output pins to the
desired state. When received the device will send a RESP_CONTROL_OUTPUT
(page 181) message.
>STKABCDDDDDDDDDDDDDDDD;PW=PPPPPPPP;ID=YYYYYYYY;*ZZ<
A
Always ‘U’: Indicates a set Control Module output message.
B
Output 1:
0=Output Low; 1=Output High; 2=No Change.
C
Output 2:
0=Output Low; 1=Output High; 2=No Change.
DDDD
DDDD
DDDD
DDDD
Reserved for future use.
16 digits. Must be sent as
‘0000000000000000’.
PPPPPPPP
Security Password
.
Always 8 alphanumeric characters, UPPER
CASE ONLY.
Default 00000000
YYYYYYYY
Unit ID.
Always 8 alphanumeric characters, UPPER CASE ONLY
ZZ
Checksum.
Table 59, SET_CONTROL_OUTPUT Message