TrimTrac ProE Locator Technical Manual v2.0e
148
SET_APP_CONFIG
The SET_APP_CONFIG message is used by the server application to set the
primary state machine parameters in the TrimTrac ProE. When received the
TrimTrac ProE will send a RESP_APP_CONFIG (page 170) message in
response.
>STKABBBBBBCCCCCCDDDDDDEEEEEEFFFFFFGGGTTHIJK;PW=PPPPPPP
P;ID=YYYYYYYY;*ZZ<
A
TrimTrac Configuration Set:
‘A’ = Application Parameters
BBBBBB
IDLE Timeout, T1
.
In seconds (10 – 999990)
. Default 43200
CCCCCC
FIX Timeout, T2
.
In seconds (10 – 3600)
. Default 300
DDDDDD
TRANSMIT Timeout, T3
.
In seconds (10 – 3600)
Less than 300 not
recommended. Default 300
EEEEEE
DELAY Timeout, T4
.
In seconds (10 – 86400)
. Default 900
FFFFFF
QUERY Timeout, T5
.
In seconds (10 – 3600)
. Default 60
GGG
Almanac Timeout, T6
.
In hours (10 – 990)
. Default 168
TT
Static Motion Filter Timeout, T7
.
In seconds (0 – 90). Note: T7 is
used exclusively
while in the IDLE
state;
however, it is superseded
by
the Dynamic Motion Filter
Timeout, T21, whenever Anytime Polling
is:
A.
Set “2=Anytime OnDemand”;
OR
B. Set “1-Duty-Cycled”
and Polling Duty-Cycle On-Time, T20, is
running.
Always
set Static Motion Filter Timeout, T7, greater than or equal
to Static Motion Filter Counter, N3. Default 20
H
Motion Report Flag
.
0=None
1=Start Motion Report
2=Stop Motion Report
3=
Start & Stop Motion Reports. Default 0
I
Report Delay Flag
.
0=Transmit (“Tx”) All Messages
1=Tx Exception Reports & Query/Set
Responses only
2=Tx Motion-related, Exceptions &
Responses
3=Tx IDLE Timeout, T1, Status Msgs, Exceptions
& Responses
4=Tx Start/Stop, IDLE
Status, Exceptions & Responses
5=Tx every 6th motion-triggered message, Exceptions &
Respones
6=Tx every 11th motion-triggered message, Exceptions & Respones
7=Tx Start/Stop, Exception & Responses (No IDLE Status)
. Default 0
J
Diagnostics Mode
.
0= None; 1= LED
. Default 1
K
Communication Mode
.
0= SMS; 1= GPRS; 2=AutoSelect
.
Default 0
PPPPPPPP
Security Password
.
Always 8 alphanumeric characters, UPPER CASE
ONLY.
Default 00000000
YYYYYYYY
Unit ID.
Always 8 alphanumeric characters, UPPER CASE ONLY
ZZ
Checksum.
Table 58, SET_APP_CONFIG Message
Summary of Contents for ProE Locator
Page 112: ...TrimTrac ProE Locator Technical Manual v2 0e 94 Figure 24 HPA Processing in TRANSMIT ...
Page 113: ...TrimTrac ProE Locator Technical Manual v2 0e 95 Figure 25 MPA Processing in TRANSMIT ...
Page 114: ...TrimTrac ProE Locator Technical Manual v2 0e 96 Figure 26 LPA Processing in TRANSMIT ...
Page 177: ...TrimTrac ProE Locator Technical Manual v2 0e 159 ...
Page 178: ...TrimTrac ProE Locator Technical Manual v2 0e 160 ...
Page 205: ...TrimTrac ProE Locator Technical Manual v2 0e 187 Quick Reference Tables ...
Page 232: ...TrimTrac ProE Locator Technical Manual v2 0e 214 Figure 37 Control Module Wiring Diagram ...