User Guide
TransCore Proprietary
7-6
102N Select Parity
Command
!102N
selects the reader parity setting. The factory-default setting is parity
disabled. The N variable specifies parity as shown in
Table 7 – 3
.
Table 7 – 3 Select Parity Commands
Reader response:
Done
Command Group 2
Group 2 commands control the real-time clock which maintains the AI1422E internal time
and date. This time and date can be appended to IDs, error messages, and sensor input
reports. An internal battery supports the clock, so time and date are preserved if main
power is lost.
20 Set Time
Command
!20
sets the time. Enter the time in the proper format: two-digit decimal entries
with no spaces between characters and using colons as delimiters. The entry format is as
follows:
20HH:MM:SS or 20HH:MM:SS:hh
where
HH
represents hours (00 to 23).
MM
represents minutes (00 to 59).
SS
represents seconds (00 to 59).
hh
represents hundredths of a second (00 to 99).
:
is the time delimiter.
If hundredths of a second is not specified, the reader sets the hundredths register to 00.
Reader response:
Done
Command
Data Bits
Parity Selected
1020
8
Disable parity (factory default)
1021
7
Select even parity
1022
7
Select odd parity
Summary of Contents for 1422E
Page 16: ...Before You Begin 1...
Page 20: ...AI1422E Reader TransCore Proprietary 1 5...
Page 21: ...2 System Overview...
Page 25: ...AI1422E Reader TransCore Proprietary 2 5 Figure 2 2 Antenna to Tag Centerline Tolerance...
Page 26: ......
Page 27: ...3 Interface Connections...
Page 32: ...User Guide TransCore Proprietary 3 6...
Page 33: ...4 Installation Instructions...
Page 41: ...AI1422E Reader TransCore Proprietary 4 9...
Page 42: ...5 System Test Procedures...
Page 45: ......
Page 46: ...6 Communications Protocols...
Page 49: ......
Page 50: ...7 Command Codes...
Page 87: ...User Guide TransCore Proprietary 7 38...
Page 88: ...8 Troubleshooting and Maintenance...
Page 93: ......
Page 94: ...Character Conversion A...
Page 96: ...B Technical Specifications...
Page 99: ......