27
The following example assumes that the scale system uses four
Transcell SBS-2.5K
load cells.
All required information can be obtained from its datasheet, type label, and/or accompanying pa-
per summary sheet(s).
The
Transcell SBS-2.5K
load cell has a rated capacity of 2500 pounds, and a rated output
of 3 mV/V.
F52
menu
Value
F52-1
1 (Enable)
F52-2
1 (lb)
F52-3
2500
F52-4
4
F52-5
3.0000 (*)
mV/V Calibration Value Entry Table (example)
(*) for greater accuracy, use the average of the four rated outputs found on the paper sum-
mary sheets included with each load cell.
Balance of page intentionally left blank