15
CODE/NAME
DESCRIPTION
SELECTION LIST
F30
Special Appli-
cation
Used to select one special application feature, subject to local legal
requirements.
“0” = None (Gross/Net)”, “1” = Accumulation, “2” = Remote Display,
“3” = Piece Count, “5” = Hold, “6” = Checkweigher
0
1
2 3
5 6
F31
Gross Zero
Band
Selects the range within which the scale will automatically clear the
tare and switch to Gross mode. Note that the scale must be in stand-
still. Selections are in display divisions (d). Scrolling down with the
ZERO key one level begins the procedure.
“0” = Disabled
Key-in
0 - 10
0
F32
Center of Zero
Band
Selects the range around gross zero within which the scale will display
the Center of Zero annunciator. Selections are in display divisions (d).
0.25
0.5
F34
Auto Print Min.
Weight
Selects the minimum weight at which the auto print function will work
if enabled. Selections are in display divisions (d). Scrolling down with
the ZERO key one level begins the procedure.
“0” = Disabled
Key-in
0 - 100
1
F35
Hold Mode
This mode of operation is enabled by setting F30 to “5”. This mode
captures the weight of an unstable load, e.g. livestock, by freezing
the weight on the display. Use the Motion Band setting (F5) and the
Percentage Hold setting (F37) to adjust this mode to your specific ap-
plication. When the weight has been locked onto the display, two ar-
rows beneath the weight display will be turned ON.
"0" = Off
AUTOMATIC (F35 = 1)
– Automatically locks weight on the display
when stable. If the weight of the object on the scale changes by the
F12 setting (e.g. 10%) then the sale unlocks the held reading and re-
locks onto the new weight. This occurs during both increasing and
decreasing weight values.
MANUAL (F35= 2)
– Press the NET/GROSS key before applying any
weight to the scale. After the load has stabilized, the display will hold
the weight reading on the screen until the NET/GROSS key is
pressed again. If the weight of the object on the scale changes by the
F12 setting (e.g. 10%) then the sale unlocks the held reading and re-
locks onto the new weight. This occurs during increasing weight val-
ues only
.
PEAK HOLD (F35= 3)
– The display updates as the load increases
but not as the load decreases. The value shown on the screen is the
maximum weight applied to the scale. Press the UNITS key to toggle
between live mode and peak hold mode. The ‘P’ annunciator is used
to indicate that you are in Peak Hold mode. When you exit out of
peak hold mode, the old peak value is automatically cleared
.
0
1
2
3
F36
Percentage
Hold Weight
Allows you to select the percentage (of the displayed held value) of
weight change before the scale automatically unlocks the held weight
and relocks onto the new weight
. If F35 is set to “0”, this function does
nothing.
Key-in
0
– 100 %
10