SS-SVX11K-EN
65
Disconnect Switch External Handle
(Factory Mounted Option)
Figure 43.
Disconnect switch details
Control Box Door
Disconnect
Switch
External
Handle
Locking
Slot
Locking
Thumb Key
Under Handle
Units ordered with the factory mounted nonfused
disconnect switch comes equipped with an externally
mounted handle. This allows the operator to
disconnect power from the unit without having to open
the control panel door. Handle locations and its three
positions are shown below:
•
“ON” - Indicates disconnect switch is closed,
allowing main power supply to be applied at unit.
•
“OFF” - Indicates disconnect switch is open,
interrupting main power supply to unit controls.
•
“OPEN COVER/RESET” - Turning the handle to this
position releases the handle form the disconnect
switch, allowing the control panel door to be
opened.
Once the door has been opened, it can be closed with
the handle in any one of the three positions outlined
above, provided it matches the disconnect switch
position.
The handle can be locked in the “OFF” position. While
holding the handle in the “OFF” position, push the
spring loaded thumb key, attached to the handle, into
the base slot. Place the lock shackle between the
handle and the thumb key. This will prevent it from
springing out of position.
Main Unit Power Wiring
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o
p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
W
WA
AR
RN
NIIN
NG
G
P
Prro
op
pe
err F
Fiie
elld
d W
Wiirriin
ng
g a
an
nd
d G
Grro
ou
un
nd
diin
ng
g
R
Re
eq
qu
uiirre
ed
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w cco
od
de
e cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
sse
erriio
ou
uss iin
njju
urry
y..
A
Allll ffiie
elld
d w
wiirriin
ng
g M
MU
US
ST
T b
be
e p
pe
errffo
orrm
me
ed
d b
by
y q
qu
ua
alliiffiie
ed
d
p
pe
errsso
on
nn
ne
ell.. IIm
mp
prro
op
pe
errlly
y iin
nsstta
alllle
ed
d a
an
nd
d g
grro
ou
un
nd
de
ed
d
ffiie
elld
d w
wiirriin
ng
g p
po
osse
ess F
FIIR
RE
E a
an
nd
d E
EL
LE
EC
CT
TR
RO
OC
CU
UT
TIIO
ON
N
h
ha
azza
arrd
dss.. T
To
o a
av
vo
oiid
d tth
he
esse
e h
ha
azza
arrd
dss,, y
yo
ou
u M
MU
US
ST
T ffo
ollllo
ow
w
rre
eq
qu
uiirre
em
me
en
nttss ffo
orr ffiie
elld
d w
wiirriin
ng
g iin
nsstta
alllla
attiio
on
n a
an
nd
d
g
grro
ou
un
nd
diin
ng
g a
ass d
de
essccrriib
be
ed
d iin
n N
NE
EC
C a
an
nd
d y
yo
ou
urr llo
occa
all//
sstta
atte
e//n
na
attiio
on
na
all e
elle
eccttrriicca
all cco
od
de
ess..
N
NO
OT
TIIC
CE
E
U
Usse
e C
Co
op
pp
pe
err C
Co
on
nd
du
ucctto
orrss O
On
nlly
y!!
F
Fa
aiillu
urre
e tto
o u
usse
e cco
op
pp
pe
err cco
on
nd
du
ucctto
orrss cco
ou
ulld
d rre
essu
ulltt iin
n
e
eq
qu
uiip
pm
me
en
ntt d
da
am
ma
ag
ge
e a
ass tth
he
e e
eq
qu
uiip
pm
me
en
ntt w
wa
ass n
no
ott
d
de
essiig
gn
ne
ed
d o
orr q
qu
ua
alliiffiie
ed
d tto
o a
acccce
ep
ptt o
otth
he
err tty
yp
pe
ess o
off
cco
on
nd
du
ucctto
orrss..
See
“Power Wire Sizing and Protection Devices,” p. 66
for field connection wire ranges for main power
terminal block 1TB1 and optional disconnect switch
1S1.
See Electrical Data tables for unit electrical data. The
electrical service must be protected from over current
and short circuit conditions in accordance with NEC
requirements. Protection devices must be sized
according to the electrical data on the nameplate.
•
See Calculation — MCA, MOP, and RDE in
section to determine the
following:
–
Electrical service wire size based on Minimum
Circuit Ampacity (MCA),
–
Maximum Overcurrent Protection (MOP) device.
–
Recommended Dual Element fuse size (RDE).
•
If the unit is not equipped with an optional factory
installed non-fused disconnect switch, a field
supplied disconnect switch must be installed at or
near the unit in accordance with the National
Electrical Code (latest edition). See Calculation —
Disconnect Switch Sizing (DSS) in
section to determine the
correct size.
•
Complete the unit’s power wiring connections onto
either the main terminal block 1TB1, or the factory
mounted non-fused disconnect switch 1S1, inside
the unit control panel. Refer to the customer
connection diagram that shipped with the unit for
specific termination points.
•
Provide proper grounding for the unit in accordance
with local and national codes.