700 Series
2-7
❑
Battery pack
Error code
Meaning
10h
Battery voltage is over the maximum allowed limit.
11h
Battery charge current is over the maximum allowed limit.
12h
Battery discharge current is over the maximum allowed limit when
there is no load.
13h
Battery charge current is over the maximum allowed limit.
❑
B5V, VCC power supply output
Error code
Meaning
20h
B5V voltage is over the maximum allowed limit.
21h
B5V voltage is below the minimum allowed limit.
22h
B5V or VCC does not start up when the power supply is turned on.
23h
VCC voltage is below the minimum allowed limit.
24h
During suspend, B5V voltage is below the minimum allowed limit.
❑
B3V output
Error code
Meaning
30h
B3V Voltage is over the maximum allowed limit.
31h
B3V Voltage is below the minimum allowed limit.
32h
B3V does not start when the power supply is turned on.
33h
B3V is below the minimum allowed limit during suspend.
❑
P12V Output
Error code
Meaning
40h
P12V Voltage is over the maximum allowed limit.
41h
P12V Voltage is below the minimum allowed limit.
42h
P12V does not start when the power supply is turned on.
❑
Power supply microcontroller
Error code
Meaning
50h
Firmware or program error.
❑
Environmental condition
Error code
Meaning
80h
CPU temperature is outside the allowable range.
Summary of Contents for Tecra 700CS
Page 4: ...1 4 700 Series Figure 1 2 700 Series system unit configuration ...
Page 20: ...1 20 700 Series ...
Page 23: ...700 Series 2 3 Figure 2 1 Troubleshooting flowchart 2 2 ...
Page 54: ...2 34 700 Series ...
Page 124: ...3 70 700 Series ...
Page 180: ...4 56 700 Series ...
Page 186: ...B 2 700 Series B 2 System Board Back View Figure B 2 System Board layout back ...
Page 218: ...G 2 700 Series ...