700 Series
2-9
Procedure 3
Connection Check
The power supply wiring diagram is shown below:
Any of the connectors may be disconnected. Perform Check 1.
Check 1
Make sure the AC adapter’s cable and AC cord are firmly plugged into the DC IN
15 V socket and wall outlet. If these cables are connected correctly, go to Check
2.
Check 2
Connect a new AC adapter.
❑
If the DC IN icon does not glow green, go to Procedure 5.
❑
If the Battery icon does not glow orange, go to Check 3.
Check 3
Make sure the battery pack is installed in the computer correctly. If the battery is
properly installed and the Battery icon still does not glow orange, go to Procedure
4.