3-4
700 Series
2.
To select the DIAGNOSTIC TEST menu from the DIAGNOSTICS MENU, set
the highlight bar to
1
, and press
Enter
. The following menu will appear:
TOSHIBA personal computer xxx DIAGNOSTICS
version X.XX (c) copyright TOSHIBA Corp. 19XX
DIAGNOSTIC TEST menu :
1 - SYSTEM TEST
2 - MEMORY TEST
3 - KEYBOARD TEST
4 - DISPLAY TEST
5 - FLOPPY DISK TEST
6 - PRINTER TEST
7 - ASYNC TEST
8 - HARD DISK TEST
9 - REAL TIMER TEST
10 - NDP TEST
11 - EXPANSION TEST
12 - SOUND TEST
13 - CD-ROM TEST
88 - ERROR RETRY COUNT SET [HDD & FDD]
99 - EXIT TO DIAGNOSTICS MENU
↑ ↓ → ←
:
Select items
Enter
:
Specify
Esc
:
Exit
Refer to Sections 3.4 through 3.16 for detailed descriptions of Diagnostic Tests 1
through 13. Function 88 sets the floppy disk drive and hard disk drive error retry
count. Function 99 exits the submenus of the Diagnostic Test and returns to the
Diagnostic Menu.
3.
Select the option you want to execute and press
Enter
. The following message
will appear:
SYSTEM TEST XXXXXXX
xxx DIAGNOSTIC TEST VX.XX
[Ctrl]+[Break]
; test end
[Ctrl]+[C]
; key stop
SUB-TEST : XX
PASS COUNT: XXXXX ERROR COUNT: XXXXX
WRITE DATA: XX READ DATA : XX
ADDRESS : XXXXXX STATUS : XXX
SUB-TEST MENU :
01 - ROM checksum
02 -
03 -
04 - Fan ON/OFF
05 - Thermister check
06 - Serial ID check
99 - Exit to DIAGNOSTIC TEST menu
↑ ↓ → ←
:
Select items
Enter
:
Specify
Esc
:
Exit
Summary of Contents for Tecra 700CS
Page 4: ...1 4 700 Series Figure 1 2 700 Series system unit configuration ...
Page 20: ...1 20 700 Series ...
Page 23: ...700 Series 2 3 Figure 2 1 Troubleshooting flowchart 2 2 ...
Page 54: ...2 34 700 Series ...
Page 124: ...3 70 700 Series ...
Page 180: ...4 56 700 Series ...
Page 186: ...B 2 700 Series B 2 System Board Back View Figure B 2 System Board layout back ...
Page 218: ...G 2 700 Series ...